Bulb: One spare bulb
Bulb type: Stainless bulb
Blades: 3 Macintosh blades
Handle: Standard Knurled
Blade Dimension: Large : 160mm Medium : 130mm Small: 100mm
Range of measurement: | Lens | Range |
|---|---|
| Sphere | -25 ~ +25 D unit( 0.01/0.12/0.25 D steps) |
| Cylinder | -9.99 ~ +9.99 D unit (0.01/0.12/0.25 D steps) |
| Axis | 0° ~ 180° unit (1° steps) |
| Add | 0 ~ +9.99 D unit (0.01/0.12/0.25 D) |
| Prism | 0 ~ 6 △ unit ( 0.01/0.12/0.25 △) |
Lens measurement type: | Lens | Type |
|---|---|
| Cylinder | +,+/-,- |
| Prism | X-Y,P-B |
| Contact lens | Soft/hard |
Measuring mode: Single Progressive Auto recognition
Diameter of lens: ¢20 mm ~ 108 mm
PD: 45 mm ~ 90mm, 0.25mm steps
Type: Two-channel for independent outputs
Test Signal: Pure tone, Pulse tone, Warble tone, Narrowband noise
Output: TDH 39 Air conduction headset(L/R), B71 Bone conduction headset(L/R), Free Sound field
Input: Tone and Speech
Attenuation level: -10 dB ~ 120 dB
Generator Type: High frequency inverter 80 kHz
Radiographic Ratings: Large focal point, 20-35 kV/10-510 mAs
Focal Size: Dual focus 0.2/0.4 mm
Input Power: Single phase AC 220 V, 50-60 Hz
Power Ratings: 6 kW
Generator Type: High frequency inverter 40 kHz
Radiographic Ratings: Large focal point, 20-35 kV/10-510 mAs
Focal Size: Dual focus 0.5 mm
Input Power: Single phase AC 220 V, 50-60 Hz
Power Ratings: 1.8 kW
Display Size: 12” Color LCD Triplex display
Display Modes: B/BB/B/M/CD/PWD/CWD/DIR PWR/PWR
Imaging Technology: 3D/4D Imaging
Image Format: AVI, JPG, TIF, BMP, SEQ, DICOM 3.0
Beam Formation: DAS Technology
Display: 3” TFT panel, 4:3 ratio
Magnification: Optical : 20-200 X Digital : 500 X
Image sensor: 5 MP
Still image resolution: 12 M (4030x3024), 9 M, 5 M, 3 M, 1.3 M, VGA
Video capture resolution: VGA, QVGA
Tube Voltage: 60 kV
Tube Current: 8 mA
Exposure Time: 0.2 s – 4 s
Tube Focus: 0.8 mm
Tube Voltage: 60 kV
Tube Current: 8 mA
Exposure Time: 0.2 s – 4 s
Tube Focus: 0.8 mm
Tube Voltage: 60 kV
Tube Current: 1 mA
Exposure Time: 0.02 s – 2 s
Tube Focus: 0.3 x 0.3 mm
Tube Voltage: 90 kVp
Tube Current: 10 mA
Exposure Time: 16 s
Tube Focus: 0.8 mm
Film Size: 150 × 300 mm
LCD Display: 192 x 64 Graphic
Paper Speed: 5 / 6.25 / 10 / 12.5 / 25 / 50 (mm/s)
Sensitivity: 2.5, 5, 10, 20, 40 (mm/mV), Auto
Safety Standard: IEC Class I, Type CF
LCD Display: 3.8 inch Graphic
Expandable Storage: Up to 250 ECGs
Paper Speed: 5 / 6.25 /10 / 12.5 / 25 / 50 (mm/s)
Sensitivity: 2.5, 5, 10, 20, 40 (mm/mV), Auto
Safety Standard: IEC Class I, Type CF
LCD Display: 6” LCD real-time
Expandable Storage: Up to 250 ECGs
Paper Speed: 5 / 6.25 / 10 / 12.5 / 25 / 50 (mm/s)
Sensitivity: 2.5, 5, 10, 20, 40 (mm/mV), Auto
Safety Standard: IEC Class I, Type CF
LCD Display: 6” Real-time display
Expandable Storage: Up to 1008 ECGs
Paper Speed: 5 / 6.25 / 10 / 12.5 / 25 / 50 (mm/s)
Sensitivity: 2.5, 5, 10, 20, 40 (mm/mV), Auto
Safety Standard: IEC Class I, Type CF
Otoscope: 1
Size ear speculum: 3
Ophthalmoscope: 1
Nasal Speculum: 1
Ben arm Illuminator: 1
Input channel: (19 Monopolar EEG and 1 Bipolar ECG)
Recording modes: Real-time (via Bluetooth) / Dynamic (via Flash memory)
Sampling Rate: 128, 256, 512 Hz
A/ Converter: 12 bit
Input channel: 32/64/128 channels Monopolar EEG
Recording modes: Real-time
Sampling Rate: 128, 256, 512, 1024, 2048, 4096, 8192 Hz
Evoke Stimulator: A/V Simulator/ Video Signal, Current Stimulator
A/ Converter: 24 bit
Input channel: (12/24/36/48 Monopolar EEG+12channelsBipolar EEG+12channels PSG)
Recording modes: Real-time
Sampling Rate: 128, 256, 512, 1024, 2048, 4096, 8192 Hz
A/ Converter: 24 bit
Number of channels: 4 channel
Stimulus Modes: Single-current, Dual-current Stimulator
Stimulus Frequency: 0.1 Hz ~ 50 Hz
Sample Rate: 200 KHz
Analysis Time: 1 ms ~ 1000 ms
Ultrasound frequency: 2 MHz
Ultrasound Intensity: <10mW/cm2
Screen: Alphanumeric LCD
Display: Digital FHR
FHR Measuring range: 50 ~ 240 bpm
Ultrasound frequency: 2 MHz
Ultrasound Intensity: <10mW/cm2
Screen: Color LCD
Display: FHR and curve
FHR Measuring range: 50 ~ 240 bpm
Focal Distance: 430 × 430 mm
Source Head Range: 550 mm - 1820 mm
Exposure Time: 0.08 s - 6.32 s
Focal Distance: 350 x 350 mm
Source Head Range: 520 mm - 1880 mm
Exposure DC Voltage: 100 kV ; 50 kV - 100 kV
Exposure DC Current: 35 A (instant)
Exposure Time: 0.08 s - 6.32 s
Inverter Frequency: 50 kHz
Tube Voltage: 40 kV – 120 kV (interval 1 kV)
Operational Access: Wired/Wireless Control
Current: 1.0–180 mAs (46 steps)
Power Rating: 5 kVA
Inverter Frequency: 50 kHz
Tube Voltage: 40 kV – 120 kV (interval 1 kV)
Operational Access: Wired/Wireless Control
Current: 1.0–180 mAs (46 steps)
Power Rating: 5 kVA
Inverter Frequency: 50 kHz
Tube Voltage: 40 kV – 100 kV (interval 1 kV)
Operational Access: Wired/Wireless Control
Current: 1.0–125 mAs (43 steps)
Power Rating: 3.5 kVA
Light source: LED bulb
Luminance: About 18.5 lumen
Lens: Glass lens with 3 X magnification
Ear Specula sizes: 2.4 mm 3 mm 4 mm 5 mm
Patient groups: Infant to Adults
Flow range: 1 L/s ⁓ 16 L/s
Volume range: 10 L
Flow accuracy: ± 10 %
Volume Accuracy: ± 3 %
Trend: Flow rate – Volume
Exposure Voltage: 50 kV ~ 90 kV
Exposure Current: Small focus: 25 mA Big focus: (50, 75, 100 and 125) mA
Max. Output Voltage: 90 kV
Max. Output Current: 100 mA
Exposure Time: 0.04 s ~ 6.3 s, 23 grades
Exposure Voltage: 50 kV ~ 100 kV
Exposure Current: Small focus: 50 mA
Big focus: (50, 100, 150 and 200) mA
Max. Output Voltage: 100 kV
Max. Output Current: 200 mA (instant) 5 mA (running)
Exposure Time: 0.04 s ~ 6.3 s, 23 grades
Exposure Voltage: 50 kV ~ 125 kV
Exposure Current: Small focus: (50, 100) mA
Big focus: (50, 100, 200 and 300) mA
Max. Output Voltage: 120 kV
Max. Output Current: 300 mA (instant)
Exposure Time: 0.04 s ~ 6.3 s, 23 grades
No. of Channels: 10
No. of Sample Analysis: 5
Specificity: 1
Sensitivity: 0.95
Range of CO2 Concentration: 0.5 % ─ 6 %
Display size: 15-inch LCD screen
Display depth: 250 mm
Ultrasound modes: B, B+B, B+M, M, 4B
TGC: Total gain, 8 segment TGC
Display size: 15-inch LCD screen
Display depth: 250 mm
Display view: ≥ 152°
Ultrasound modes: B, B+B, B+M, M, 4B
TGC: Total gain, 8 segment TGC
Display Size: 10-inch screen
Display Depth: ≥ 250 mm
Ultrasound Modes: B, B+B, B+M, B+2M, M, 4B
TGC: Total gain, 8 segment TGC
Depth Adjustability: 16 level of real-time depth adjustments
Display Size: 10-inch screen
Display Depth: ≥ 250 mm
Ultrasound Modes: B, B+B, B+M, B+2M, M, 4B
TGC: Total gain, 8 segment TGC
Depth Adjustability: 16 level of real-time depth adjustments
Display Size: 12-inch LCD screen
Display Depth: 40mm to 250 mm
Ultrasound Modes: B, B+B, B+M, M, 4B
TGC: Total gain, 8 segment TGC
Depth Adjustability: 16 level of real-time depth adjustments
Image Sensor: 1/4″ Super HAD color CCD
CCD Resolution (HD optional): 8,00,000 pixels
Horizontal Resolution: ≥ 470 TV lines
Magnification: Optical : 10 x to 60 x Digital : Up to 128 x
Light Source: Halogen cold light source with bright White multi-point LED ring
Max Output Power: 4 kW
Nominal Power: 100 kV, 40mA, 0.1 s, 4 kW
Input Power: 220 V ± 2 V (AC); 50/60 Hz
Tube Focus-spot: 0.6 / 1.5 mm
Digital Detectors: Limit Resolution : 3.6 LP/mm Pixel Area : 427 × 356 mm A/D conversion : 14 bit