logo

Laboratory Analyser

Chemistry Analyser KCA-A200
  • list pointType: Fully Automated Analysis system
  • list pointThroughput: 140 tests per hour
  • list pointAnalytical Methods: End point, Kinetic, fixed time, Bi-chromatic, multi-standard, Two steps of end point and more
  • list pointAssay Modules: Over 200 modules
  • list pointSample Slots: 64 slots for standard and control
Chemistry Analyser KCA-A201
  • list pointType: Fully Automated Random Access System
  • list pointThroughput: Reagent 1 : 400 test/hr
    Reagent 2 : 600 test/hr
    With ISE : 400 test/hr
  • list pointAnalytical Methods: End-point, Multi-standard, Immuno-turbid metric, 1-2 reagent, Reagent/serum blank, etc.
  • list pointAssay Modules: 80 modules
  • list pointSample Slots: 80
Chemistry Analyser KCA-A202
  • list pointType: Fully Automatic Random Access system
  • list pointThroughput: 120 tests/hour
  • list pointAssay Modules: Up to 26 Assays
  • list pointSample slots: 9
  • list pointSample volume: 3 µL – 45 µL, (0.5 µL step adjustability)
Coagulation Analyser KCG-A100
  • list pointNumber of channels: Single channel
  • list pointTest parameters: PT [Prothrombin Time]
    APTT [Activated Partial Thromboplastin Time]
    TT [Thrombin Time]
    FBG [Fibrinogen Concentration]
    Clotting Factors
  • list pointMeasurement method: Photometric analysis
  • list pointDisplay: Back-illuminated LCD
  • list pointReagent volume: 50 µl ~ 100µl
HbA1c analyzer KGH-A100
  • list pointMeasurement range: 3 % ~ 18 %
  • list pointTesting parameters: Precision (CV) < 3 %
    Accuracy (V) < 1.5 %
  • list pointSample type: Venous blood (EDTA anticoagulation), Peripheral finger blood
  • list pointSample volume: 5 µl whole blood for each sample
  • list pointPhotometer: 415 nm LED integral flow colorimeter
Haematology Analyser KHA-A100
  • list pointType: Fully automated 3-part differential system
  • list pointThroughput: 60 samples/hr
  • list pointTesting Parameters: WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.
  • list pointAccuracy (CV %): WBC (109/L) : 2.0 % (7.0 - 15.0)
    RBC (1012/L) : 1.5 % (3.50 - 6.00)
    HGB (g/L) : 1.5 % (110 - 180)
    MCV (fL) : 0.4 % (80.0 - 110.0)
    PLT (109/L) : 4 % (100 - 500)
Haematology Analyser KHA-A101
  • list pointType: Fully automated 3-part differential system
  • list pointThroughput: 60 samples/hr
  • list pointTesting Parameters: WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.
  • list pointAccuracy (CV %): WBC (109/L) : 2.0 % (7.0 - 15.0)
    RBC (1012/L) : 1.5 % (3.50 - 6.00)
    HGB (g/L) : 1.5 % (110 - 180)
    MCV (fL) : 0.4 % (80.0 - 110.0)
    PLT (109/L) : 4 % (100 - 500)
Haematology Analyser KHA-A200
  • list pointType: Fully automated 3-part differential system
  • list pointThroughput: 60 samples/hr
  • list pointTesting Parameters: WBC, LY, LY%, MO, MO%,GR,GR%,RBC,HGB,HCT, MCV,RDW-SD, RDWCV, MCH, MCHC, PLT, MPV, PCT, PDW with Histograms for WBC, RBC and PLT.
  • list pointAccuracy (CV %): WBC ≤ 2.0 %
    RBC ≤ 1.5 %
    PCT ≤ 3.0 %
    PLT ≤ 5.0 %
    HGB ≤ 1.5 %
    MCV ≤ 1.0 %
    MPV ≤ 3.0 %
    PDW ≤ 3.0 %
    MCH ≤ 2.0 %
    MCHC ≤ 2.0 %
Haematology Analyser KHA-B100
  • list pointType: Fully automated 5-part differential system
  • list pointThroughput: 60 samples/hr
  • list pointTesting Parameters: WBC, RBC, HGB. HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%, ALY#, ALY%, IG#, IG%, 2 histograms, 2 scatter grams.
  • list pointAccuracy (CV %): WBC (109/L) : 2.0 %
    RBC (1012/L) : 1.5 %
    HGB (g/L) : 1.5 %
    PLT (109/L) : 4 %
Veterinary Haematology Analyser KHA-C100
  • list pointType: Fully automated 3-part differential system
  • list pointThroughput: 30 samples/hr
  • list pointPrinciple of Operation: Impedance, SFT method
  • list pointAccuracy (CV %): WBC(109/L) : 2.0 %
    RBC (1012/L) : 1.5 %
    HGB (g/L) : 1.5 %
    MCV (fL) : 0.5 %
    PLT (109/L) : 4.0 %
Veterinary Haematology Analyser KHA-C101
  • list pointType: Fully automated 5-part differential system
  • list pointThroughput: 60 samples/hr
  • list pointPrinciple of Operation: Impedance, Colorimetry
  • list pointAccuracy (CV %): WBC (109/L) : (0 - 100)
    RBC (1012/L) : (0 - 1700)
    HGB (g/L) : (0 - 250)
    PLT(109/L) : (0 - 3000)
Urine analyzer KUA-A100
  • list pointMethod: RGB Tricolor test
  • list pointTest mode: Single-step test
  • list pointStrip compliance: 8, 10, 11, 12, 14 parameter test strips
  • list pointMemory: Stores up to 500 records
  • list pointRepeatability: CV ≤ 1%