  • list pointType: Fully automated 3-part differential system
  • list pointThroughput: 60 samples/hr
  • list pointTesting Parameters: WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.
  • list pointAccuracy (CV %): WBC (109/L) : 2.0 % (7.0 - 15.0)
    RBC (1012/L) : 1.5 % (3.50 - 6.00)
    HGB (g/L) : 1.5 % (110 - 180)
    MCV (fL) : 0.4 % (80.0 - 110.0)
    PLT (109/L) : 4 % (100 - 500)
Haematology Analyser KHA-A101
  • list pointType: Fully automated 3-part differential system
  • list pointThroughput: 60 samples/hr
  • list pointTesting Parameters: WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.
  • list pointAccuracy (CV %): WBC (109/L) : 2.0 % (7.0 - 15.0)
    RBC (1012/L) : 1.5 % (3.50 - 6.00)
    HGB (g/L) : 1.5 % (110 - 180)
    MCV (fL) : 0.4 % (80.0 - 110.0)
    PLT (109/L) : 4 % (100 - 500)
Haematology Analyser KHA-A200
  • list pointType: Fully automated 3-part differential system
  • list pointThroughput: 60 samples/hr
  • list pointTesting Parameters: WBC, LY, LY%, MO, MO%,GR,GR%,RBC,HGB,HCT, MCV,RDW-SD, RDWCV, MCH, MCHC, PLT, MPV, PCT, PDW with Histograms for WBC, RBC and PLT.
  • list pointAccuracy (CV %): WBC ≤ 2.0 %
    RBC ≤ 1.5 %
    PCT ≤ 3.0 %
    PLT ≤ 5.0 %
    HGB ≤ 1.5 %
    MCV ≤ 1.0 %
    MPV ≤ 3.0 %
    PDW ≤ 3.0 %
    MCH ≤ 2.0 %
    MCHC ≤ 2.0 %
Haematology Analyser KHA-B100
  • list pointType: Fully automated 5-part differential system
  • list pointThroughput: 60 samples/hr
  • list pointTesting Parameters: WBC, RBC, HGB. HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%, ALY#, ALY%, IG#, IG%, 2 histograms, 2 scatter grams.
  • list pointAccuracy (CV %): WBC (109/L) : 2.0 %
    RBC (1012/L) : 1.5 %
    HGB (g/L) : 1.5 %
    PLT (109/L) : 4 %
Veterinary Haematology Analyser KHA-C100
  • list pointType: Fully automated 3-part differential system
  • list pointThroughput: 30 samples/hr
  • list pointPrinciple of Operation: Impedance, SFT method
  • list pointAccuracy (CV %): WBC(109/L) : 2.0 %
    RBC (1012/L) : 1.5 %
    HGB (g/L) : 1.5 %
    MCV (fL) : 0.5 %
    PLT (109/L) : 4.0 %
Veterinary Haematology Analyser KHA-C101
  • list pointType: Fully automated 5-part differential system
  • list pointThroughput: 60 samples/hr
  • list pointPrinciple of Operation: Impedance, Colorimetry
  • list pointAccuracy (CV %): WBC (109/L) : (0 - 100)
    RBC (1012/L) : (0 - 1700)
    HGB (g/L) : (0 - 250)